Solar water heating with collectors and no circulation pump
An integrated collector-storage unit does without several components that are usual in solar thermal systems and offers solar heat as a complete package. Besides its simple design, its price is fairly low and the collector is relatively easy to move. However, it also has some disadvantages, which show above all in northern latitudes.
The collector-storage unit: absorber and tank in one
In solar thermal technology, a system usually consists of a collector, which produces heat from sunlight, and a storage tank, where the heat is collected and supplied to the household. This technology is used in all common solar systems with flat-plate or tube collectors.
An integrated collector-storage unit combines the collector and the tank in a single component. The tank sits directly beneath the absorber surface. Both are housed in an insulated casing and connected directly to the water pipes. Cold water flows into the lower part of the unit, and the heated water leaves the collector at the top. Water temperatures of 20 to 95 °C can be reached.

A simple design
The advantage of an integrated collector-storage unit is that many components such as heat exchangers and pumps are not needed, which makes it inexpensive.
It does have some drawbacks, though. The water temperature in the unit drops much faster at low outside temperatures than in tanks inside the house. The unit is also very heavy, because of the weight of the water on the roof. A storage volume of only up to around 400 litres is therefore possible.
In Lanzarote and the other Canary Islands, with their very high solar radiation, an integrated collector-storage unit is well worth it. Here it is often used in solar thermal systems.
We offer two types of thermosiphon system
Type 1
The domestic water is stored in the solar tank (e.g. 200 litres). There it is heated by the heating circuit that is driven thermally by sunlight on the solar collector.
Advantage:
→ The system can be built very low (about as high as a satellite dish), which is an advantage in shared apartment and holiday complexes.
Disadvantage:
→ At least every 30 days the system must be heated to over 60 °C for 24 hours so that no germs, bacteria or salmonella can develop in the solar tank and domestic water.

Type 2
All the water in the solar tank (e.g. 200 litres) is used as heating water. It is heated by the heating circuit driven thermally by sunlight on the solar collector.
When needed, the domestic water flows through stainless steel pipes laid inside the tank and is heated as it flows through.
In principle this works just like an instantaneous water heater.
Advantages:
→ The domestic water can no longer be contaminated (germs, bacteria or salmonella) through long standing times or too low temperatures.
This type of tank is called a hygienic tank and has long been used in larger, pump-driven solar systems.
→ The system needs almost no maintenance.
→ No sacrificial anode needs replacing.
→ The heating element is no longer attacked and damaged by chlorine and salt residues.
→ The system can be operated unpressurised.
→ The service life of the solar system is extended enormously.
Disadvantage:
→ None! The system is only about 35 cm taller than type 1.